Fire Alarm Control Panels
Flex 510 Fire Alarm Control Panel
Flex Series fire alarm control panels provide reliable fire signaling protection for medium-sized commercial, industrial, and institutional buildings.
The Flex 510 is a ten-zone fire alarm control panel (FACP) . This combination control and digital communicator panel provides reliable fire signaling protection for medium-sized commercial, industrial and institutional buildings.
Initiating Device Circuits (IDCs) for Flex Series panels are programmable and operate in Class B (Style B). Each panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, water flow devices, tamper switches and other normally-open contact devices. This includes System Sensor i3™ Series microprocessor-based detectors with advanced features, like drift compensation, maintenance alert and freeze warning.
Features & Benefits:- Style B (Class B) initiating device circuits (IDCs) - ten programmable IDCs
- Built-in digital alarm communicator/transmitter (DACT)
- Four Style Y (Class B) notification appliance circuits (NACs) programmable for: ADA compliant strobe synchronization, Selective silence (horn/strobe mute), Temporal or steady signal, silence able or non-silence able, Auto-silence and silence inhibit
- Three programmable Form-C relays
- 24 VDC special application power outputs (resettable and non-resettable)
- Optional Class A converter module for NACs and IDCs (model CAC-5X)
- Optional transmitter module for municipal box service and reverse polarity (model 4XTMF)
- Completely field programmable at keypad. Needs no special software or extra equipment; two password protected programming levels
- 80-character, backlit, high-angle, LCD display
- UL: S1869
- FM Approved:
- MEA Approved:
- CSFM: 7300-1703: 0166
- The VMC Group (Seismic): VMA-45894-02C (Revision 1)
- ISO 9001 Certification
Others
- Maximum Operating Humidity
- 93 Percentage
- Minimum Operating Humidity
- 2 Percentage
- Standby Current
- 2 milliampere
- Output Current
- 15 milliampere
- Maximum Battery Capacity
- 18
- Operating Voltage
- 120 voltage alternating current
- 3.8 ampere
- For Use With
- Backbox
- Loop Capacity
- 10
- 404
- Main Frequency
- 60 HTZ
Others
- Maximum Operating Humidity
- 93 Percentage
- Minimum Operating Humidity
- 2 Percentage
- Standby Current
- 2 milliampere
- Output Current
- 15 milliampere
- Maximum Battery Capacity
- 18
- Operating Voltage
- 120 voltage alternating current
- 3.8 ampere
- For Use With
- Backbox
- Loop Capacity
- 10
- 404
- Main Frequency
- 60 HTZ
- Maximum Operating Humidity : 93 Percentage
- Minimum Operating Humidity : 2 Percentage
- Standby Current : 2 milliampere
- Output Current : 15 milliampere
- Maximum Battery Capacity : 18
- Operating Voltage : 120 voltage alternating current|3.8 ampere
- For Use With : Backbox
- Loop Capacity : 10|404
- Main Frequency : 60 HTZ