/content/hbtbt/dk/en/search-results.html

    Monitor Modules

    AMM-4SF Addressable Monitor Module

    Addressable sub-loop monitor modules are designed for installation in the signaling line circuit of any Gamewell-FCI® analog addressable control panel.

    Overview

    Addressable monitor modules AMM-4SF feature a single Style D, Class A initiating device circuit. They may also be configured as a Style B, Class B initiating circuit with an end-of-line resistor. These modules provide an address for a group of conventional 2-wire smoke detectors. Any alarm initiating devices with normally open dry contacts such as heat detectors, manual stations, linear heat detection devices, water flow switches, 4-wire smoke detectors, and tamper switches may also be installed in the circuit.

    Addressable monitor modules are designed to be installed with the signaling line circuit in any Gamewell-FCI® analog addressable fire alarm control panel. The signaling line circuits of Gamewell-FCI analog addressable panels are designed to accommodate up to 159 monitor modules per circuit. The initiating device circuit of the module can support a maximum line resistance of up to 25 ohm. This feature allows the use of linear heat detection devices. In addition, it allows the modules to stay in alarm with one smoke detector activated. Addressable monitor modules are designed to mount in a 4-inch square box.

    Features & Benefits:
    • Accommodates up to 20 conventional 2-wire smoke detectors
    • Provides visual rotary, decimal switch addressing (01 to 159)
    • Compact size allows easy installation
    • Displays bi-color LEDs, which flash green whenever the module is addressed and light steady red on alarm*
    • * Only the red LED is operative in panels that do not operate in Velociti® mode
    Certifications:
    • UL: S1949, 2572 for Mass Notification
    • FM: 3023594
    • MEA FDNY: 227-03-E Vol. IV
    • CSFM: 73100-1703:0122
    • ISO 9001 Certification
    Specifications

    Others

    • Maximum Operating Humidity
      • 0.93
    • Cabinet Width
      • 4 inch
    • Cabinet Height
      • 4 inch
    • End of Line Resistance
      • 47 kO
    • Normal Input Current
      • 270 µA
    • Minimum External Power Supply Voltage
      • 24 VDC
    • Alarm Current
      • 0.0051 ampere
    • Cabinet Depth
      • 2-1/8 inch
    • Maximum Operating Voltage
      • 15 - 32 DC volt
      • 15 VDC
    • Mounting Type
      • Wall-Mount
    • Number of Zones
      • 1
    • For Use With
      • 4 Wire Smoke Detector
      • Heat Detector
      • Linear Heat Detection Device
      • Manual Station
      • Tamper Switch
      • Water Flow Switch
    • Maximum IDC Wiring Resistance
      • 25 Ohms
    • Supported Wiring Configuration
      • Class B
    • Approved Location
      • CSFM 73100-1703-0122
      • FM 3023594
      • ISO 9001 Certified
      • MEA FDNY:227-03-E Vol. IV
      • UL S1949, 2572 for Mass Notification
      • UL Standard 864 9th Edition, UL 2572 for Mass Notification

    Others

    • Maximum Operating Humidity
      • 0.93
    • Cabinet Width
      • 4 inch
    • Cabinet Height
      • 4 inch
    • End of Line Resistance
      • 47 kO
    • Normal Input Current
      • 270 µA
    • Minimum External Power Supply Voltage
      • 24 VDC
    • Alarm Current
      • 0.0051 ampere
    • Cabinet Depth
      • 2-1/8 inch
    • Maximum Operating Voltage
      • 15 - 32 DC volt
      • 15 VDC
    • Mounting Type
      • Wall-Mount
    • Number of Zones
      • 1
    • For Use With
      • 4 Wire Smoke Detector
      • Heat Detector
      • Linear Heat Detection Device
      • Manual Station
      • Tamper Switch
      • Water Flow Switch
    • Maximum IDC Wiring Resistance
      • 25 Ohms
    • Supported Wiring Configuration
      • Class B
    • Approved Location
      • CSFM 73100-1703-0122
      • FM 3023594
      • ISO 9001 Certified
      • MEA FDNY:227-03-E Vol. IV
      • UL S1949, 2572 for Mass Notification
      • UL Standard 864 9th Edition, UL 2572 for Mass Notification
    • Maximum Operating Humidity : 0.93
    • Cabinet Width : 4 inch
    • Cabinet Height : 4 inch
    • End of Line Resistance : 47 kO
    • Normal Input Current : 270 µA
    • Minimum External Power Supply Voltage : 24 VDC
    • Alarm Current : 0.0051 ampere
    • Cabinet Depth : 2-1/8 inch
    • Maximum Operating Voltage : 15 - 32 DC volt|15 VDC
    • Mounting Type : Wall-Mount
    • Number of Zones : 1
    • For Use With : 4 Wire Smoke Detector|Heat Detector|Linear Heat Detection Device|Manual Station|Tamper Switch|Water Flow Switch
    • Maximum IDC Wiring Resistance : 25 Ohms
    • Supported Wiring Configuration : Class B
    • Approved Location : CSFM 73100-1703-0122|FM 3023594|ISO 9001 Certified|MEA FDNY:227-03-E Vol. IV|UL S1949, 2572 for Mass Notification|UL Standard 864 9th Edition, UL 2572 for Mass Notification
    Others
    Name
    Description
    File Size
    Date
    Size
    E3 Series A and E Specification - Voice (DOCX)
    application/vnd.openxmlformats-officedocument.wordprocessingml.document 78.49 KB
    6/16/2023
    78.49 KB
    E3 Series A and E Specification - Stand Alone (DOCX)
    application/vnd.openxmlformats-officedocument.wordprocessingml.document 86.29 KB
    8/1/2023
    86.29 KB
    E3 Series A and E Specification - Network (PDF)
    application/pdf 356.91 KB
    8/1/2023
    356.91 KB
    E3 Series A and E Specification - Stand Alone (PDF)
    application/pdf 353.47 KB
    8/1/2023
    353.47 KB
    AMM-4SF Interface Module (Velociti Series)
    application/pdf 651.26 KB
    5/8/2023
    651.26 KB
    E3 Series A and E Specification - Network (DOCX)
    application/vnd.openxmlformats-officedocument.wordprocessingml.document 84.55 KB
    8/1/2023
    84.55 KB
    Supplement to Compatibility Addendum-Installation Manual
    application/pdf 86.59 KB
    8/8/2023
    86.59 KB
    E3 Series A and E Specification - Voice (PDF)
    application/pdf 421.32 KB
    8/1/2023
    421.32 KB
    Brochure
    Name
    Description
    File Size
    Date
    Size
    Isolator Load Rating Table Brochure
    application/pdf 38.09 KB
    8/9/2023
    38.09 KB
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    AMM-4SF Serie Velociti Data Sheet
    application/pdf 315.09 KB
    5/14/2023
    315.09 KB
    PS Series Power Supplies - HPF-PS6 and HPF-PS10 Data Sheet
    application/pdf 237.83 KB
    5/14/2023
    237.83 KB
    AMM-4S Monitor Module Data Sheet
    application/pdf 193.85 KB
    5/14/2023
    193.85 KB
    AMM-4SF Addressable Monitor Module Data Sheet
    application/pdf 95.46 KB
    5/14/2023
    95.46 KB
    AMM-4 Monitor Module Data Sheet
    application/pdf 193.71 KB
    5/14/2023
    193.71 KB
    Catalog
    Name
    Description
    File Size
    Date
    Size
    Engineering and Applications Catalog
    application/pdf 131.74 KB
    5/10/2023
    131.74 KB
    Name
    Description
    File Size
    Date
    Size
    E3 Series A and E Specification - Voice (DOCX)
    application/vnd.openxmlformats-officedocument.wordprocessingml.document 78.49 KB
    6/16/2023
    78.49 KB
    E3 Series A and E Specification - Stand Alone (DOCX)
    application/vnd.openxmlformats-officedocument.wordprocessingml.document 86.29 KB
    8/1/2023
    86.29 KB
    AMM-4SF Serie Velociti Data Sheet
    application/pdf 315.09 KB
    5/14/2023
    315.09 KB
    E3 Series A and E Specification - Network (PDF)
    application/pdf 356.91 KB
    8/1/2023
    356.91 KB
    E3 Series A and E Specification - Stand Alone (PDF)
    application/pdf 353.47 KB
    8/1/2023
    353.47 KB
    PS Series Power Supplies - HPF-PS6 and HPF-PS10 Data Sheet
    application/pdf 237.83 KB
    5/14/2023
    237.83 KB
    AMM-4S Monitor Module Data Sheet
    application/pdf 193.85 KB
    5/14/2023
    193.85 KB
    AMM-4SF Interface Module (Velociti Series)
    application/pdf 651.26 KB
    5/8/2023
    651.26 KB
    Engineering and Applications Catalog
    application/pdf 131.74 KB
    5/10/2023
    131.74 KB
    AMM-4SF Addressable Monitor Module Data Sheet
    application/pdf 95.46 KB
    5/14/2023
    95.46 KB
    E3 Series A and E Specification - Network (DOCX)
    application/vnd.openxmlformats-officedocument.wordprocessingml.document 84.55 KB
    8/1/2023
    84.55 KB
    Isolator Load Rating Table Brochure
    application/pdf 38.09 KB
    8/9/2023
    38.09 KB
    AMM-4 Monitor Module Data Sheet
    application/pdf 193.71 KB
    5/14/2023
    193.71 KB
    Supplement to Compatibility Addendum-Installation Manual
    application/pdf 86.59 KB
    8/8/2023
    86.59 KB
    E3 Series A and E Specification - Voice (PDF)
    application/pdf 421.32 KB
    8/1/2023
    421.32 KB
    Name
    Description
    File Size
    Date
    Size
    E3 Series A and E Specification - Voice (DOCX)
    78.49 KB
    6/16/2023
    E3 Series A and E Specification - Stand Alone (DOCX)
    86.29 KB
    8/1/2023
    E3 Series A and E Specification - Network (PDF)
    356.91 KB
    8/1/2023
    E3 Series A and E Specification - Stand Alone (PDF)
    353.47 KB
    8/1/2023
    AMM-4SF Interface Module (Velociti Series)
    651.26 KB
    5/8/2023
    E3 Series A and E Specification - Network (DOCX)
    84.55 KB
    8/1/2023
    Supplement to Compatibility Addendum-Installation Manual
    86.59 KB
    8/8/2023
    E3 Series A and E Specification - Voice (PDF)
    421.32 KB
    8/1/2023
    Isolator Load Rating Table Brochure
    38.09 KB
    8/9/2023
    AMM-4SF Serie Velociti Data Sheet
    315.09 KB
    5/14/2023
    PS Series Power Supplies - HPF-PS6 and HPF-PS10 Data Sheet
    237.83 KB
    5/14/2023
    AMM-4S Monitor Module Data Sheet
    193.85 KB
    5/14/2023
    AMM-4SF Addressable Monitor Module Data Sheet
    95.46 KB
    5/14/2023
    AMM-4 Monitor Module Data Sheet
    193.71 KB
    5/14/2023
    Engineering and Applications Catalog
    131.74 KB
    5/10/2023
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime