Flame Detectors
Multi-Spectrum™ SS2 Electro-Optical Fire Detector
Multi-Spectrum™ SS2 electro-optical fire detectors provide ultra-high speed responses to explosive fires and feature programming to assure ultra-high speed millisecond response.
Multi-Spectrum™ SS2 electro-optical fire detectors provide ultra-high speed responses to explosive fires and are typically used in munitions production, explosives production, and special applications. The detectors sense radiant energy in the UV, visible, and WideBand Infrared™ spectrum. The radiant energy from all types of flaming fires will alert the detector to its presence. The SS2 electro-optical fire detectors feature programming to assure ultra-high speed millisecond response to normal non-sodium azide burning materials radiating UV and IR energy for munitions and air bag industries.
Features & Benefits:- Detects hydrocarbon and non-hydrocarbon based fires
- Wide field of view or solar blind
- Explosion-proof housing
- Detects hydrocarbon and non-hydrocarbon based fires
- Wide field of view and solar blind
- Greatest sensitivity with false alarm immunity
- Microprocessor based algorithms FirePic™ and Tri-Mode Plot™
- Wide temperature range of operation
- Explosion-proof housing
- FS2000™ System compatible or standalone operation
- Class I, Div. 1 & 2, Groups A, B, C, and D
- Class II, Div. 1 & 2, Groups E, F, and G
- Class III
Others
- Minimum Operating Humidity
- 10 (Non-Condensing) percentage relative humidity
- Maximum Operating Humidity
- 90 (Non-condensing) percentage relative humidity
- Maximum Operating Ambient Temperature
- 185 degree Fahrenheit
- 85 degree Celsius
- Minimum Operating Ambient Temperature
- -40°C
- -40°F
- Power Consumption
- 100 (Alarm Condition) milliampere
- 89 (Normal Operation) milliampere
Others
- Minimum Operating Humidity
- 10 (Non-Condensing) percentage relative humidity
- Maximum Operating Humidity
- 90 (Non-condensing) percentage relative humidity
- Maximum Operating Ambient Temperature
- 185 degree Fahrenheit
- 85 degree Celsius
- Minimum Operating Ambient Temperature
- -40°C
- -40°F
- Power Consumption
- 100 (Alarm Condition) milliampere
- 89 (Normal Operation) milliampere
- Minimum Operating Humidity : 10 (Non-Condensing) percentage relative humidity
- Maximum Operating Humidity : 90 (Non-condensing) percentage relative humidity
- Maximum Operating Ambient Temperature : 185 degree Fahrenheit|85 degree Celsius
- Minimum Operating Ambient Temperature : -40°C|-40°F
- Power Consumption : 100 (Alarm Condition) milliampere|89 (Normal Operation) milliampere