Transmitter Modules
MIP-2UD IP Communicator
MIP-2UD IP communicators allow the transmission of alarms generated by a conventional control panel through any kind of IP network (ADSL, cable, internet), at the same time that it keeps the standard telephone line as a backup mechanism.
MIP-2UD IP communicators allow the transmission of alarms generated by a conventional control panel through any kind of IP network (ADSL, cable, internet), at the same time that it keeps the standard telephone line as a backup mechanism. Designed to work with the installed control panels, these communicators allow for a faster and more economic alarm transmission, improving response times, decreasing costs, and offering value-added features such as the supervised line functionality that allows the central station to detect if any of the alarm panels go offline.
Features & Benefits:- Allows any contact ID burglar alarm panel to transmit alarms over IP networks
- Saves the cost of an 800 number to receive alarms (transmission is done through a flat rate internet connection that is shared with other devices)
- Eliminates the cost of two dedicated phone lines (only the customer’s shared IP equipment is required)
- Can use newer low-cost, non-analog, digital telephone services such as cable or fiber optics
- Increases connection supervision to the central station from the once-a-day test signal to once every 30 to 90 seconds
- Requires no change to the existing panel configuration (the IP communicator connects directly to the primary and secondary analog panel telephone ports)
- Fast alarm transmission (less than one second transmission time) for better response times to burglar alarms
- Works over any type of customer-provided Ethernet 10/100 base network connection (LAN or WAN), DSL or cable modem
- Data transmits over standard contact ID protocol but is secured with the industry’s highest level of encryption (AES 512-bit)
- Supports both dynamic (DHCP) or public and private static IP addressing
Others
- Maximum Operating Voltage
- 24 voltage direct current
- Alarm Current
- 104 mA @ 24 voltage direct current
- 180 mA @ 12 voltage direct current
- Operating Voltage
- 10
- 24 voltage direct current
- Minimum Operating Ambient Temperature
- -2 degree Celsius
- -3 degree Fahrenheit
- Communication Protocols
- AES
- DHCP
- IP
- RJ-45 (Female)
- SRP
- UDP
- Minimum Operating Humidity
- 0.02
- Input Power
- 10/24 V DC
- Includes
- Configuration Software
- Manual
- Maximum Operating Humidity
- 0.93
Others
- Maximum Operating Voltage
- 24 voltage direct current
- Alarm Current
- 104 mA @ 24 voltage direct current
- 180 mA @ 12 voltage direct current
- Operating Voltage
- 10
- 24 voltage direct current
- Minimum Operating Ambient Temperature
- -2 degree Celsius
- -3 degree Fahrenheit
- Communication Protocols
- AES
- DHCP
- IP
- RJ-45 (Female)
- SRP
- UDP
- Minimum Operating Humidity
- 0.02
- Input Power
- 10/24 V DC
- Includes
- Configuration Software
- Manual
- Maximum Operating Humidity
- 0.93
- Maximum Operating Voltage : 24 voltage direct current
- Alarm Current : 104 mA @ 24 voltage direct current|180 mA @ 12 voltage direct current
- Operating Voltage : 10|24 voltage direct current
- Minimum Operating Ambient Temperature : -2 degree Celsius|-3 degree Fahrenheit
- Communication Protocols : AES|DHCP|IP|RJ-45 (Female)|SRP|UDP
- Minimum Operating Humidity : 0.02
- Input Power : 10/24 V DC
- Includes : Configuration Software|Manual
- Maximum Operating Humidity : 0.93