I/O Modules
CIPer™ Model 30 Expansion Module
CIPer Model 30 small (7 I/O) and large (20 I/O) expansion modules.
CIPer Model 30 Expansion modules provide addition I/O for CIPer Model 30 Controllers. Multiple expansion I/O modules can be connected to a single controller and different size modules can be mixed any combination to meet specific project I/O requirements.
Features & Benefits:- Direct connect to the CIPer Model 30 Controller or remote mount up to100 ft away
- Can be powered by the CIPer Model 30 Controller
- All wiring connections are made to removable terminal blocks to simplify device installation and replacement.
- Wide range of sensors supported sensors like 20KNTC, PT1000 and other resistive sensors.
- Multiple Expansion I/O capability support. Refer to CIPer Model 30 technical documentation for more details.
- 16-bit A/D conversion resolution for accurate measurement.
- Indication LEDs for all Digital and Analog Outputs (DO & AO).
- HOA (Hand-Off-Auto) switches on DOs and AOs. HOA are configurable and can be monitored.
- Compact size for small installation housings.
- Field configurable and programmable for control, input, and output functions using the Niagara Framework®based CIPer Model 30 programming tool.
Others
- Minimum Operating Voltage
- 20 voltage alternating current
- Relay Current
- 1.5 ampere
- Minimum Operating Humidity
- 5% (Non-Condensing)
- Maximum Power Consumption
- 100 volt amp
- Maximum Operating Humidity
- 95% (Non-Condensing)
- Maximum Output Voltage
- 20 - 30 voltage alternating current
- 30 voltage alternating current
- Minimum Operating Ambient Temperature
- -20 degree Celsius
- -4 degree Fahrenheit
- Maximum Operating Voltage
- 20 - 30 voltage alternating current
- 30 voltage alternating current
- Control Software
- WEBs-N4
- For Use With
- CIPer 30
- Terminal Type
- Removable
- Approved Location
- FCC Part 15
- Type
- I/O Module
- Concentrator Type
- 2-Wired
- Mounting Type
- DIN Rail
- Panel
Others
- Minimum Operating Voltage
- 20 voltage alternating current
- Relay Current
- 1.5 ampere
- Minimum Operating Humidity
- 5% (Non-Condensing)
- Maximum Power Consumption
- 100 volt amp
- Maximum Operating Humidity
- 95% (Non-Condensing)
- Maximum Output Voltage
- 20 - 30 voltage alternating current
- 30 voltage alternating current
- Minimum Operating Ambient Temperature
- -20 degree Celsius
- -4 degree Fahrenheit
- Maximum Operating Voltage
- 20 - 30 voltage alternating current
- 30 voltage alternating current
- Control Software
- WEBs-N4
- For Use With
- CIPer 30
- Terminal Type
- Removable
- Approved Location
- FCC Part 15
- Type
- I/O Module
- Concentrator Type
- 2-Wired
- Mounting Type
- DIN Rail
- Panel
- Minimum Operating Voltage : 20 voltage alternating current
- Relay Current : 1.5 ampere
- Minimum Operating Humidity : 5% (Non-Condensing)
- Maximum Power Consumption : 100 volt amp
- Maximum Operating Humidity : 95% (Non-Condensing)
- Maximum Output Voltage : 20 - 30 voltage alternating current|30 voltage alternating current
- Minimum Operating Ambient Temperature : -20 degree Celsius|-4 degree Fahrenheit
- Maximum Operating Voltage : 20 - 30 voltage alternating current|30 voltage alternating current
- Control Software : WEBs-N4
- For Use With : CIPer 30
- Terminal Type : Removable
- Approved Location : FCC Part 15
- Type : I/O Module
- Concentrator Type : 2-Wired
- Mounting Type : DIN Rail|Panel