/content/hbtbt/gb/en/search-results.html

    Zone & Unitary Controllers

    Stryker™ LON Configurable VAV Controller

    Stryker™ LON configurable variable air volume (VAV) controllers are used for either pressure-independent, pressure single-duct VAV terminal units, or constant volume air-handling unit control solutions.

    Overview

    Stryker™ LON configurable variable air volume (VAV) controllers are used for either pressure-independent, pressure single-duct VAV terminal units, or constant volume air-handling unit control solutions. These controllers feature preprogrammed heat/cooling or reheat algorithms for VAV box control applications and can be configured to match a wide range of VAV applications. They contain an integral microbridge airflow sensor that provides flow measurement for pressure independent applications.

    Features & Benefits:
    • Reduces engineering and maintenance time, and ensures proper operation
    • Quick configuration saves time for system integrators
    • Built-in VAV control applications
    • Uses the Echelon® LonWorks® network protocol
    • Field configurable for control, input, and output functions using the Niagara Framework® software, or Zio® wall module
    • Capable of standalone operation, but can also use LonWorks® Bus network communications
    • Sylk™ bus for use with Sylk-enabled devices
    • 120 controllers per network with router when configured as a repeater
    • Significant event notification, periodic update capability, and failure detect when network inputs fail to be updated within their configurable time frame
    • All wiring connections are made to removable 
    Certifications:
    • UL/cUL (E87741) Listed Under UL916 (Standard for Open Energy Management Equipment) with Plenum Rating
    • CSA (LR95329-3) Listed
    • Meets FCC Part 15, Subpart B, Class B (Radiated Emissions) Requirements
    • Meets Canadian Standard C108.8 (Radiated Emissions)
    Specifications

    Others

    • Maximum Operating Humidity
      • 95% (Non-Condensing)
    • Minimum Operating Humidity
      • 5% (Non-Condensing)
    • Communications Protocol
      • LonWorks
    • For Use With
      • WEBs-AX
      • WEBs-N4
    • Control Software
      • WEBs-AX
    • Power Source
      • Power Supply
    • Number of Universal Inputs
      • 4
    • Control Functions
      • Built-in Zone
    • Number of digital inputs
      • 0
    • Application
      • VAV
    • Communication Technology
      • LonWorks

    Others

    • Maximum Operating Humidity
      • 95% (Non-Condensing)
    • Minimum Operating Humidity
      • 5% (Non-Condensing)
    • Communications Protocol
      • LonWorks
    • For Use With
      • WEBs-AX
      • WEBs-N4
    • Control Software
      • WEBs-AX
    • Power Source
      • Power Supply
    • Number of Universal Inputs
      • 4
    • Control Functions
      • Built-in Zone
    • Number of digital inputs
      • 0
    • Application
      • VAV
    • Communication Technology
      • LonWorks
    • Maximum Operating Humidity : 95% (Non-Condensing)
    • Minimum Operating Humidity : 5% (Non-Condensing)
    • Communications Protocol : LonWorks
    • For Use With : WEBs-AX|WEBs-N4
    • Control Software : WEBs-AX
    • Power Source : Power Supply
    • Number of Universal Inputs : 4
    • Control Functions : Built-in Zone
    • Number of digital inputs : 0
    • Application : VAV
    • Communication Technology : LonWorks
    Reference Guides
    Name
    Description
    File Size
    Date
    Size
    System Engineering Guide
    application/pdf 4.7 MB
    5/11/2023
    4.7 MB
    Brochure
    Name
    Description
    File Size
    Date
    Size
    Brochure for TR71, TR75, TR71H, TR75H, CVL4022AS, CVL4024NS Stryker Controllers Evolved (English)
    application/pdf 407.78 KB
    5/11/2023
    407.78 KB
    Engineering Specifications
    Name
    Description
    File Size
    Date
    Size
    Specification Data
    application/pdf 798.68 KB
    5/10/2023
    798.68 KB
    Installation Instructions
    Name
    Description
    File Size
    Date
    Size
    Installation Instructions for CVL4022AS, CVL4024NS, CUL6438SR Stryker- Lon Configurable VAV-CVAHU Controllers (English)
    application/pdf 3.09 MB
    5/8/2023
    3.09 MB
    Configuration Guide
    application/pdf 3.8 MB
    5/8/2023
    3.8 MB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    User Guide
    application/pdf 457.93 KB
    5/10/2023
    457.93 KB
    Name
    Description
    File Size
    Date
    Size
    System Engineering Guide
    application/pdf 4.7 MB
    5/11/2023
    4.7 MB
    User Guide
    application/pdf 457.93 KB
    5/10/2023
    457.93 KB
    Installation Instructions for CVL4022AS, CVL4024NS, CUL6438SR Stryker- Lon Configurable VAV-CVAHU Controllers (English)
    application/pdf 3.09 MB
    5/8/2023
    3.09 MB
    Specification Data
    application/pdf 798.68 KB
    5/10/2023
    798.68 KB
    Brochure for TR71, TR75, TR71H, TR75H, CVL4022AS, CVL4024NS Stryker Controllers Evolved (English)
    application/pdf 407.78 KB
    5/11/2023
    407.78 KB
    Configuration Guide
    application/pdf 3.8 MB
    5/8/2023
    3.8 MB
    Name
    Description
    File Size
    Date
    Size
    System Engineering Guide
    4.7 MB
    5/11/2023
    Brochure for TR71, TR75, TR71H, TR75H, CVL4022AS, CVL4024NS Stryker Controllers Evolved (English)
    407.78 KB
    5/11/2023
    Specification Data
    798.68 KB
    5/10/2023
    Installation Instructions for CVL4022AS, CVL4024NS, CUL6438SR Stryker- Lon Configurable VAV-CVAHU Controllers (English)
    3.09 MB
    5/8/2023
    Configuration Guide
    3.8 MB
    5/8/2023
    User Guide
    457.93 KB
    5/10/2023
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime