/content/hbtbt/gb/en/search-results.html

    Smoke Detectors

    Notifier NP-200 Series Photoelectric Smoke Detector

    Notifier NP-200 Series Photoelectric Smoke Detector is unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources.

    Overview
    The Notifier NP-200 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the NP-100 Series.A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with NOTIFIER’s Fire Warden Series addressable fire alarm control panels, the NP-200 Series point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The NP-200 Series also offers 135F (57C) fixed temperature thermal sensing on the NP-200T and a remote test capable detector on the NP-200R for use with DNR(A)/DNRW duct smoke detector housings.Features & Benefits:
    • Sleek, low-profile design
    • Available in both Bright White (for new installations) and Ivory (for legacy installations)
    • Photoelectric smoke detection
    • Analog communications
    • Low standby current
    • Rotary address switches
    • Dual LEDs for 360° visibility
    Certifications:
    • UL/ULC Listing: S1115
    • FM Approved
    • CSFM: 7272-0028:0503
    Specifications

    Others

    • Maximum Operating Voltage
      • 15 - 32 (Peak) voltage direct current
    • Maximum Standby Current
      • 200 µA @ 24 voltage direct current
    • Maximum Operating Humidity
      • 93 Percentage
    • Minimum Operating Humidity
      • 10 Percentage
    • Sensitivity
      • 0.5 - 3.5 Percentage
      • 0.5 - 4 Percentage
    • Conventional or Addressable
      • Addressable
    • Detection Sensor Type
      • Photoelectric
    • Material
      • Plastic
    • Wiring Type
      • 2-Wire

    Others

    • Maximum Operating Voltage
      • 15 - 32 (Peak) voltage direct current
    • Maximum Standby Current
      • 200 µA @ 24 voltage direct current
    • Maximum Operating Humidity
      • 93 Percentage
    • Minimum Operating Humidity
      • 10 Percentage
    • Sensitivity
      • 0.5 - 3.5 Percentage
      • 0.5 - 4 Percentage
    • Conventional or Addressable
      • Addressable
    • Detection Sensor Type
      • Photoelectric
    • Material
      • Plastic
    • Wiring Type
      • 2-Wire
    • Maximum Operating Voltage : 15 - 32 (Peak) voltage direct current
    • Maximum Standby Current : 200 µA @ 24 voltage direct current
    • Maximum Operating Humidity : 93 Percentage
    • Minimum Operating Humidity : 10 Percentage
    • Sensitivity : 0.5 - 3.5 Percentage|0.5 - 4 Percentage
    • Conventional or Addressable : Addressable
    • Detection Sensor Type : Photoelectric
    • Material : Plastic
    • Wiring Type : 2-Wire
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    NP-200 Series Addressable Photoelectric Detectors Data Sheet
    application/pdf 264.59 KB
    5/14/2023
    264.59 KB
    Name
    Description
    File Size
    Date
    Size
    NP-200 Series Addressable Photoelectric Detectors Data Sheet
    application/pdf 264.59 KB
    5/14/2023
    264.59 KB
    Name
    Description
    File Size
    Date
    Size
    NP-200 Series Addressable Photoelectric Detectors Data Sheet
    264.59 KB
    5/14/2023
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime