Control Modules
SD500-ANM Addressable Notification Module
SD500-ANM addressable notification modules provide supervised monitoring of wiring to the load devices that require an external power supply to operate such as bells, horns, and strobes.
SD500-ANM addressable notification modules are for use with the Honeywell Silent Knight® fire alarm control panel (FACP). SD500-ANM addressable notification modulesprovide a single class A or B circuit that is controlled by the IntelliKnight® signaling line circuit (SLC). Power for the circuit is provided to the SD500-ANM module from a separate power supply, making it easy to power remote devices. The notification circuit, remote power, and communication to the SD500-ANM are supervised by the FACP. Each notification module is programmed with a unique SLC loop address. When an event that controls the notification module occurs, the notification switches its built-in relay feeding power from the auxiliary power input to the notification appliance. SD500-ANM addressable notification modulescan produce all 16 of the notification patterns available on the fire alarm control panel.
Features & Benefits:- Flexible solution for adding notification circuits where needed
- DIP switch programming for fast installation
- Support for Class B (Style Y) or Class A (Style Z) wiring
- Attractive ivory cover plate
- Polling LED visible through the cover plate
- Adds up to 127 independent output circuits on each SLC loop
- One auxiliary power source input
- Completely supervised
- UL Listed, Complies with NFPA 72
- CSFM
- MEA 429-92-E, Vol 9
- FM Approved
Others
- Maximum Operating Voltage
- 24
- Maximum Standby Current
- 6 milliampere
- Alarm Current
- 56 milliampere
- Minimum Operating Humidity
- 0 Percentage
- Maximum Operating Humidity
- 93 Percentage
- Minimum Operating Ambient Temperature
- 0 degree Celsius
- 32 degree Fahrenheit
- For Use With
- 5700:Addressable Fire Alarm Control Panel
- 5808:Addressable Fire Alarm Control Panel
- 5820XL-EVS:Addressable Fire Alarm Control Panel
- 5820XL:Addressable Fire Alarm Control Panel
- 6700:Addressable Fire Alarm Control Panel
- 6808:Addressable Fire Alarm Control Panel
- 6820:Addressable Fire Alarm Control Panel
- 6820EVS:Addressable Fire Alarm Control Panel
- Supported Wiring Configuration
- Class A
- Class B
- Approved Location
- CSFM
- FM
- MEA 429-92-E Vol 9
- UL NFPA 72
Others
- Maximum Operating Voltage
- 24
- Maximum Standby Current
- 6 milliampere
- Alarm Current
- 56 milliampere
- Minimum Operating Humidity
- 0 Percentage
- Maximum Operating Humidity
- 93 Percentage
- Minimum Operating Ambient Temperature
- 0 degree Celsius
- 32 degree Fahrenheit
- For Use With
- 5700:Addressable Fire Alarm Control Panel
- 5808:Addressable Fire Alarm Control Panel
- 5820XL-EVS:Addressable Fire Alarm Control Panel
- 5820XL:Addressable Fire Alarm Control Panel
- 6700:Addressable Fire Alarm Control Panel
- 6808:Addressable Fire Alarm Control Panel
- 6820:Addressable Fire Alarm Control Panel
- 6820EVS:Addressable Fire Alarm Control Panel
- Supported Wiring Configuration
- Class A
- Class B
- Approved Location
- CSFM
- FM
- MEA 429-92-E Vol 9
- UL NFPA 72
- Maximum Operating Voltage : 24
- Maximum Standby Current : 6 milliampere
- Alarm Current : 56 milliampere
- Minimum Operating Humidity : 0 Percentage
- Maximum Operating Humidity : 93 Percentage
- Minimum Operating Ambient Temperature : 0 degree Celsius|32 degree Fahrenheit
- For Use With : 5700:Addressable Fire Alarm Control Panel|5808:Addressable Fire Alarm Control Panel|5820XL-EVS:Addressable Fire Alarm Control Panel|5820XL:Addressable Fire Alarm Control Panel|6700:Addressable Fire Alarm Control Panel|6808:Addressable Fire Alarm Control Panel|6820:Addressable Fire Alarm Control Panel|6820EVS:Addressable Fire Alarm Control Panel
- Supported Wiring Configuration : Class A|Class B
- Approved Location : CSFM|FM|MEA 429-92-E Vol 9|UL NFPA 72