/content/hbtbt/in/en/search-results.html

    Monitor Modules

    500 Series Intelligent Module - M500DM

    The M500DM module is capable of monitoring two separate Class B circuits simultaneously, making it ideal for waterflow tamper switch and flow switch monitoring.

    Overview

    System Sensor monitor modules provide an interface to contact devices, such as security contacts, waterflow switches, or pull stations. M500DM is capable of Class B supervised wiring to the monitored device. Conventional 4-wire smoke detectors can be monitored through their alarm and trouble contacts, wired as an initiating loop to the module. In addition to transmitting the supervised state of the monitored device (normal, open, or short), the full analog supervision measurement is sent back to the panel. This allows detection of impedance changes in the supervised loop to the monitored device.

    Features & Benefits:
    • SEMS screws for easing wiring
    • Panel controlled status LED
    • Analog communications
    • Rotary address switches
    • Low standby current Mounts in standard 4˝ junction box
    Certifications:
    • FM Approved
    • UL Listed
    • ULC Listed
    Specifications

    Others

    • Minimum Operating Humidity
      • 10 Percentage
    • Minimum Operating Ambient Temperature
      • -5 degree Celsius
    • Maximum Operating Humidity
      • 93 Percentage
    • End of Line Resistance
      • 47k ohm
    • Overall Height
      • 108 millimetre
    • Overall Width
      • 94 millimetre
    • Mounting Type
      • Surface
      • Wall-Mount
    • Maximum IDC Wiring Resistance
      • 1500 OHM
    • Maximum Wire Gauge
      • 2.5 MMK

    Others

    • Minimum Operating Humidity
      • 10 Percentage
    • Minimum Operating Ambient Temperature
      • -5 degree Celsius
    • Maximum Operating Humidity
      • 93 Percentage
    • End of Line Resistance
      • 47k ohm
    • Overall Height
      • 108 millimetre
    • Overall Width
      • 94 millimetre
    • Mounting Type
      • Surface
      • Wall-Mount
    • Maximum IDC Wiring Resistance
      • 1500 OHM
    • Maximum Wire Gauge
      • 2.5 MMK
    • Minimum Operating Humidity : 10 Percentage
    • Minimum Operating Ambient Temperature : -5 degree Celsius
    • Maximum Operating Humidity : 93 Percentage
    • End of Line Resistance : 47k ohm
    • Overall Height : 108 millimetre
    • Overall Width : 94 millimetre
    • Mounting Type : Surface|Wall-Mount
    • Maximum IDC Wiring Resistance : 1500 OHM
    • Maximum Wire Gauge : 2.5 MMK
    Others
    Name
    Description
    File Size
    Date
    Size
    M500DM Dual Monitor Module Manual
    application/pdf 772.48 KB
    5/11/2023
    772.48 KB
    Intelligent Dual Input Monitor Module Engineering Specs
    application/pdf 53.76 KB
    5/14/2023
    53.76 KB
    500 Series Intelligent Modules Datasheet
    application/pdf 164.51 KB
    5/14/2023
    164.51 KB
    ISO-6 UL Listing
    application/pdf 175.39 KB
    5/17/2022
    175.39 KB
    Intelligent Dual Input Monitor Module
    application/pdf 53.76 KB
    1/21/2022
    53.76 KB
    System Sensor Loop Control Card, UL-Listed Document
    application/pdf 519.8 KB
    519.8 KB
    Installation Instructions
    Name
    Description
    File Size
    Date
    Size
    M500DMA Dual Monitor Module Installation Guide
    application/pdf 217.17 KB
    5/8/2023
    217.17 KB
    M500DM Dual Monitor Module Installation Document
    application/pdf 666.55 KB
    5/8/2023
    666.55 KB
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    500 SeriesIntelligent Modules Datasheet
    application/pdf 78.19 KB
    5/14/2023
    78.19 KB
    Name
    Description
    File Size
    Date
    Size
    M500DM Dual Monitor Module Manual
    application/pdf 772.48 KB
    5/11/2023
    772.48 KB
    M500DMA Dual Monitor Module Installation Guide
    application/pdf 217.17 KB
    5/8/2023
    217.17 KB
    Intelligent Dual Input Monitor Module Engineering Specs
    application/pdf 53.76 KB
    5/14/2023
    53.76 KB
    500 Series Intelligent Modules Datasheet
    application/pdf 164.51 KB
    5/14/2023
    164.51 KB
    M500DM Dual Monitor Module Installation Document
    application/pdf 666.55 KB
    5/8/2023
    666.55 KB
    ISO-6 UL Listing
    application/pdf 175.39 KB
    5/17/2022
    175.39 KB
    500 SeriesIntelligent Modules Datasheet
    application/pdf 78.19 KB
    5/14/2023
    78.19 KB
    Intelligent Dual Input Monitor Module
    application/pdf 53.76 KB
    1/21/2022
    53.76 KB
    System Sensor Loop Control Card, UL-Listed Document
    application/pdf 519.8 KB
    519.8 KB
    Name
    Description
    File Size
    Date
    Size
    M500DM Dual Monitor Module Manual
    772.48 KB
    5/11/2023
    Intelligent Dual Input Monitor Module Engineering Specs
    53.76 KB
    5/14/2023
    500 Series Intelligent Modules Datasheet
    164.51 KB
    5/14/2023
    ISO-6 UL Listing
    175.39 KB
    5/17/2022
    Intelligent Dual Input Monitor Module
    53.76 KB
    1/21/2022
    System Sensor Loop Control Card, UL-Listed Document
    519.8 KB
    M500DMA Dual Monitor Module Installation Guide
    217.17 KB
    5/8/2023
    M500DM Dual Monitor Module Installation Document
    666.55 KB
    5/8/2023
    500 SeriesIntelligent Modules Datasheet
    78.19 KB
    5/14/2023
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime