Fire Alarm Control Panels
Flex 404 Fire Alarm Control Panel
The Flex 404 is a four zone fire alarm control panel (FACP). This control panel provides reliable fire signaling protection for small to medium-sized retail, office, multi-family, or other similar commercial or institutional buildings.
The Flex 402 is a two zone fire alarm control panel (FACP) and the Flex 404 is a four zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized retail, office, multi-family, or other similar commercial or institutional buildings. The Initiating Device Circuits (IDCs) for the Flex Series panels are categorized as Class 2 Power-Limited and operate in Class B (Style B). Each panel is compatible with the following types of conventional input devices: two-wire and four-wire smoke detectors, water flow devices, pull stations and tamper switches.
In addition, each panel is compatible with other normally-open contact devices. These devices include the System Sensor i3™ Series microprocessor-based detectors with advanced features like drift compensation, maintenance alert and freeze warning.
Features & Benefits:- Four Style B (Class B) IDC zones, two Style Y (Class B) NACs
- Optional NAC Class A converter module
- NAC synchronization and programmability features: ADA compliant strobe synchronization, ANSI audible signals as required by NFPA 72, Silence inhibit, auto-silence, non-silence able, Selective Silence: mute horns, keep strobes lit; Temporal or steady signal
- Silent or audible walk test from front keypad
- Zone disable, alarm verification selectable per zone
- Controls: Acknowledge, Alarm, Silence, Reset, Walk test, Zone enable/disable
- LED indicators: Alarm, Supervisory, Maintenance, Trouble (one per zone): AC, NAC / Zone disable, NAC fault, System / Power Trouble, Walk test, Alarm Silence, Charger / Battery / Earth Fault (on pub)
- Alarm verification
- Low AC voltage sense, automatic battery charger
- Piezo sounder for alarm, trouble, and supervisory
- UL: S521
- NYC Fire Dept.: COA #366-04-3
- CSFM: 7300-1703: 0161
- ISO 9001 Certification
Others
- Standby Current
- 4 milliampere
- Maximum Battery Capacity
- 18
- Minimum Operating Humidity
- 2 Percentage
- Output Current
- 15 milliampere
- Maximum Operating Humidity
- 93 Percentage
- Operating Voltage
- 120 voltage alternating current
- 2.3 ampere
- Main Frequency
- 50/60 HTZ
- Loop Capacity
- 4
- 510
- For Use With
- Backbox
- System Sensor i3 Detectors
Others
- Standby Current
- 4 milliampere
- Maximum Battery Capacity
- 18
- Minimum Operating Humidity
- 2 Percentage
- Output Current
- 15 milliampere
- Maximum Operating Humidity
- 93 Percentage
- Operating Voltage
- 120 voltage alternating current
- 2.3 ampere
- Main Frequency
- 50/60 HTZ
- Loop Capacity
- 4
- 510
- For Use With
- Backbox
- System Sensor i3 Detectors
- Standby Current : 4 milliampere
- Maximum Battery Capacity : 18
- Minimum Operating Humidity : 2 Percentage
- Output Current : 15 milliampere
- Maximum Operating Humidity : 93 Percentage
- Operating Voltage : 120 voltage alternating current|2.3 ampere
- Main Frequency : 50/60 HTZ
- Loop Capacity : 4|510
- For Use With : Backbox|System Sensor i3 Detectors