/content/hbtbt/us/en/search-results.html

    Thermostats

    TC500A Commercial Thermostat

    The TC500A Commercial Connected Thermostat automatically monitors and controls indoor comfort. It controls and monitors RTU, Heat Pump equipment, and their configurations.

    Overview

    The TC500A-N Smart thermostat is an advanced, highly configurable, connected device designed for the unique needs of commercial buildings. It is suitable for conventional and heat pump applications both with or without economizer.

    The TC500A-N supports remote wireless control via Honeywell’s ConnectMe mobile app allowing occupants and facility managers to perform remote monitoring, control, and scheduling. Configuration and scheduling are also supported using BAS integration via BACnet IP or BACnet MS/TP. Superior energy efficiency, comfort, and maximum system performance are achieved via advanced scheduling, differential temperature monitoring, internal/external economizer integration, and open ADR (automated demand response) compatibility.

    The device is easily configured in three different ways including: intuitive user guided set-up, mobile Honeywell ConnectMobile app, or via BAS and TC500 Niagara Tool.

    Features & Benefits:
    • Smart commercial application thermostat with flexible customization and highly intuitive user interface
    • Supports RTU/AHU applications 5H/3C heat pump or 3H/4C conventional plus modulating heating and/or cooling for conventional systems and select FCU applications.
    • Provides modulating cooling output for inverter type or CopelandTM digital scroll compressor controllers
    • Premium color touch screen interface (edge-to-edge glass) with auto sleep mode and 3 color operating status indicator bar
    • Wireless and wired communication via Wi-Fi, Bluetooth, BACnet IP, BACnet MS/TP, and Sylk
    • Multiple, configurable levels of user privilege access such as setpoint limits, reminders, and scheduling with lockouts for advanced configurations
    • Fast and simple contractor commissioning through Honeywell Connect Mobile App, TC500 guided menu, or via Niagara BACnet tool
    • Flexible, configurable universal inputs/outputs, including (2) inputs and (2) inputs/outputs to support a wide variety of applications
    • Integrated economizer function with fault detection and predictive differential temperature monitoring for easy troubleshooting.
    • Advanced level functionality including contractor service mode, demand response, packaged economizer support, cybersecurity, freeze protection, and more
    • Weekly, holiday, and special event scheduling flexibility
    Specifications

    Others

    • Analog Output Signal
      • 2 UIOs (0-10 Vdc)
    • Supply Voltage
      • 24 voltage alternating current
    • Overall Width
      • 3.594 inch
      • 91.2 millimetre
    • Overall Height
      • 113.7 millimetre
      • 4.469 inch
    • Minimum Shipping & Storage Temperature
      • -40 degree Fahrenheit
      • -40 degree Celsius
    • Maximum Shipping & Storage Temperature
      • 150 degree Fahrenheit
      • 65.5 degree Celsius
    • For Use With
      • Indoor/Outdoor Air Temp Sensor ; Discharge or Supply air sensor ; CO2 sensor ; Mixed air sensor ; Occupancy sensor ; Dirty filter ; Proof of airflow ; Proof of waterflow ; Sylk Sensor Bus devices (TR40 series and C7400S)
    • Occupancy Sensor
      • PIR Ready
    • Changeover Method
      • Auto or Manual
    • Thermostat Switch Positions
      • HEAT-OFF-COOL-AUTO
    • Analog Inputs
      • 2 UIOs and 2 Uis (10K NTC type II, 10K NTC type III, 20K NTC, 0-10 Vdc)
    • Program Schedule
      • 7-day
    • Stages
      • 3 Heat / 3 Cool Conventional
      • 5 Heat / 3 Cool Heat Pump
    • Includes
      • 2 UIOs, 2 UIs, 8 DOs (G, Y1, Y2, Y3, W1, W2, W3, Aux)
    • Electrical Connection
      • 18-22 AWG Solid Wire
    • Network Communications
      • BACnet IP over Wi-Fi
      • BACnet MS/TP
      • Wi-Fi 802.11 b/g/n
    • Digital Output Signal
      • Relay Dry Contact (AUX)
      • Relay Output (G, Y1, Y2, Y3, W1, W2, W3)
    • Regulatory Approvals
      • CE ; FCC ; ICES ; UL/cUL ; RoHs ; REACH ; Title 24 (coming soon) ; BTL (coming soon)
    • Mounting Type
      • Wall
    • Supply Voltage Frequency
      • 50 HTZ
      • 50 hertz
      • 60 HTZ
      • 60 hertz
    • Sensor Element
      • Humidity
      • Temperature

    Others

    • Analog Output Signal
      • 2 UIOs (0-10 Vdc)
    • Supply Voltage
      • 24 voltage alternating current
    • Overall Width
      • 3.594 inch
      • 91.2 millimetre
    • Overall Height
      • 113.7 millimetre
      • 4.469 inch
    • Minimum Shipping & Storage Temperature
      • -40 degree Fahrenheit
      • -40 degree Celsius
    • Maximum Shipping & Storage Temperature
      • 150 degree Fahrenheit
      • 65.5 degree Celsius
    • For Use With
      • Indoor/Outdoor Air Temp Sensor ; Discharge or Supply air sensor ; CO2 sensor ; Mixed air sensor ; Occupancy sensor ; Dirty filter ; Proof of airflow ; Proof of waterflow ; Sylk Sensor Bus devices (TR40 series and C7400S)
    • Occupancy Sensor
      • PIR Ready
    • Changeover Method
      • Auto or Manual
    • Thermostat Switch Positions
      • HEAT-OFF-COOL-AUTO
    • Analog Inputs
      • 2 UIOs and 2 Uis (10K NTC type II, 10K NTC type III, 20K NTC, 0-10 Vdc)
    • Program Schedule
      • 7-day
    • Stages
      • 3 Heat / 3 Cool Conventional
      • 5 Heat / 3 Cool Heat Pump
    • Includes
      • 2 UIOs, 2 UIs, 8 DOs (G, Y1, Y2, Y3, W1, W2, W3, Aux)
    • Electrical Connection
      • 18-22 AWG Solid Wire
    • Network Communications
      • BACnet IP over Wi-Fi
      • BACnet MS/TP
      • Wi-Fi 802.11 b/g/n
    • Digital Output Signal
      • Relay Dry Contact (AUX)
      • Relay Output (G, Y1, Y2, Y3, W1, W2, W3)
    • Regulatory Approvals
      • CE ; FCC ; ICES ; UL/cUL ; RoHs ; REACH ; Title 24 (coming soon) ; BTL (coming soon)
    • Mounting Type
      • Wall
    • Supply Voltage Frequency
      • 50 HTZ
      • 50 hertz
      • 60 HTZ
      • 60 hertz
    • Sensor Element
      • Humidity
      • Temperature
    • Analog Output Signal : 2 UIOs (0-10 Vdc)
    • Supply Voltage : 24 voltage alternating current
    • Overall Width : 3.594 inch|91.2 millimetre
    • Overall Height : 113.7 millimetre|4.469 inch
    • Minimum Shipping & Storage Temperature : -40 degree Fahrenheit|-40 degree Celsius
    • Maximum Shipping & Storage Temperature : 150 degree Fahrenheit|65.5 degree Celsius
    • For Use With : Indoor/Outdoor Air Temp Sensor ; Discharge or Supply air sensor ; CO2 sensor ; Mixed air sensor ; Occupancy sensor ; Dirty filter ; Proof of airflow ; Proof of waterflow ; Sylk Sensor Bus devices (TR40 series and C7400S)
    • Occupancy Sensor : PIR Ready
    • Changeover Method : Auto or Manual
    • Thermostat Switch Positions : HEAT-OFF-COOL-AUTO
    • Analog Inputs : 2 UIOs and 2 Uis (10K NTC type II, 10K NTC type III, 20K NTC, 0-10 Vdc)
    • Program Schedule : 7-day
    • Stages : 3 Heat / 3 Cool Conventional|5 Heat / 3 Cool Heat Pump
    • Includes : 2 UIOs, 2 UIs, 8 DOs (G, Y1, Y2, Y3, W1, W2, W3, Aux)
    • Electrical Connection : 18-22 AWG Solid Wire
    • Network Communications : BACnet IP over Wi-Fi|BACnet MS/TP|Wi-Fi 802.11 b/g/n
    • Digital Output Signal : Relay Dry Contact (AUX)|Relay Output (G, Y1, Y2, Y3, W1, W2, W3)
    • Regulatory Approvals : CE ; FCC ; ICES ; UL/cUL ; RoHs ; REACH ; Title 24 (coming soon) ; BTL (coming soon)
    • Mounting Type : Wall
    • Supply Voltage Frequency : 50 HTZ|50 hertz|60 HTZ|60 hertz
    • Sensor Element : Humidity|Temperature
    Sort
    Others
    Document Title
    Document Type
    Language
    Brand
    File Size
    Certificate of Conformance
    0.67 MB
    Certificate of Conformance
    0.05 MB
    Data Sheet
    English
    1.53 MB
    Engineering Specifications
    0.04 MB
    Engineering Specifications
    0.03 MB
    Case Study
    English
    Honeywell Building Management Systems
    1.08 MB
    Reference Guides
    Document Title
    Document Type
    Language
    Brand
    File Size
    Installation Instructions
    Document Title
    Document Type
    Language
    Brand
    File Size
    Manuals and Guides
    Document Title
    Document Type
    Language
    Brand
    File Size
    White Paper
    Document Title
    Document Type
    Language
    Brand
    File Size
    Document Title
    Document Type
    Language
    Brand
    File Size
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime