    The IQ8FCT LP (loop powered) can be used as FCT (fire control transponder) to control and monitor external fire protection devices like fire dampers or as a technical alarm module (TAL) to monitor an external contact.

    Overview

    The IQ8FCT LP (loop powered) can be used as FCT (fire control transponder) to control and monitor external fire protection devices like fire dampers or as a technical alarm module (TAL) to monitor an external contact. The transponder is connected on the esserbus / esserbus-PLus loop of fire control system FlexES Control, IQ8Control and Compact.

    The IQ8FCT LP provides an integrated loop isolator, contact input as well as a potential free relay output, with which the mains voltage 230 V AC / 16 A can be switched directly. The module is powered by the field bus and does not require external voltage supply. In the FCT functionality a fire control device e.g. fire damper will be connected to the relay output of the IQ8FCT LP and controlled. Via the input the end positions of this external device are monitored according to the programming with configured runtime. The IQ8FCT LP is also equipped with configurable fail save functionality. If enabled, a communication loss with control panel or failure of the esserbus operating voltage results in automatic self-activation of relay output.

    Features & Benefits:
    • Intelligent fire event controls via programmable logics of the input and output of the FCT
    • Programmable time-limited impulse controls for relay output
    • Configurable fail safe functionality for relay output
    • Contact input for monitoring fire event controls
    • Output switching load up to 230 V AC / 16 A
    • Up to 127 devices per esserbus loop
    • Power supply via the field bus esserbus-PLus
    • Integrated loop isolator
    • Robust IP 65 protected surface mount housing
    Certifications:
    • Vds
    Specifications

    Others

    • Overall Height
      • 150 Millimeter-PRD
    • Overall Width
      • 116 Millimeter-PRD
    • Maximum Operating Ambient Temperature
      • 70 Degrees Celsius
    • Minimum Operating Ambient Temperature
      • -20 Degrees Celsius
    • Minimum Storage Temperature
      • -30 Degrees Celsius
    • Maximum Operating Voltage
      • 42
    • Maximum Storage Temperature
      • 75 coulomb
    • Housing Color
      • Grey
    • Regulatory Approvals
      • Vdc
    • Quiescent Current
      • 45
    • Maximum Operating Humidity
      • <95 Percentage

    Others

    • Overall Height
      • 150 Millimeter-PRD
    • Overall Width
      • 116 Millimeter-PRD
    • Maximum Operating Ambient Temperature
      • 70 Degrees Celsius
    • Minimum Operating Ambient Temperature
      • -20 Degrees Celsius
    • Minimum Storage Temperature
      • -30 Degrees Celsius
    • Maximum Operating Voltage
      • 42
    • Maximum Storage Temperature
      • 75 coulomb
    • Housing Color
      • Grey
    • Regulatory Approvals
      • Vdc
    • Quiescent Current
      • 45
    • Maximum Operating Humidity
      • <95 Percentage
    • Overall Height : 150 Millimeter-PRD
    • Overall Width : 116 Millimeter-PRD
    • Maximum Operating Ambient Temperature : 70 Degrees Celsius
    • Minimum Operating Ambient Temperature : -20 Degrees Celsius
    • Minimum Storage Temperature : -30 Degrees Celsius
    • Maximum Operating Voltage : 42
    • Maximum Storage Temperature : 75 coulomb
    • Housing Color : Grey
    • Regulatory Approvals : Vdc
    • Quiescent Current : 45
    • Maximum Operating Humidity : <95 Percentage
    Sort
    Document Title
    Document Type
    Language
    Brand
    File Size
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime