/content/hbtbt/us/en/search-results.html

    I/O Modules

    Panel Bus I/O Module

    Panel Bus Modules consists of a terminal socket and removable electronic module allowing socket to be mounted and wired before the electronic module is installed. They are swapped out without disrupting the power.

    Overview
    The CentraLine Panel Bus I/O Modules communicate via the Panel Bus. The pluggable CentraLine Panel Bus I/O modules consist of a terminal socket and a removable electronic module, allowing the socket to be mounted and wired before the electronic module is installed. All such electronic modules can be swapped out without disrupting the power and bus connections: Simply unplug the "old" and insert the "new" module.Features & Benefits:
    • Plug-and-play functionality
    • Easy maintenance
    • Pluggable Panel Bus I/O modules can be exchanged without rewiring.
    • Lower risk of damage and theft
    • Fast wiring with state-of-the-art push-in terminals
    • Configurable safety position for outputs
    • Max. wiring flexibility due to optional accessories
    • Can be mounted in small installation housings
    • Flexible mix of Panel Bus I/O modules
    Certifications:
    • Approvals and Certifications  CE-approved
    •  Conforms to EN 60730-1 and EN 60730-2-9
    •  Investigated according to United States Standard
    • UL916 (USL-listed) as well as according to Canadian
    • National Standard(s) C22.2 (CNL-listed)
    • Classification according to EN60730-1
    • Environmental conditions: For use in home (residential,
    • commercial, and light-industrial)
    • environments
    • Pollution degree: Class 2
    • Protection against shock: Class II
    • Software class: Class A
    • Overvoltage category: II
    • Classification according to EN60529
    • (Degree of Protection Provided by Enclosures)
    • Classification: IP20
    Specifications

    Others

    • Minimum Shipping & Storage Temperature
      • -20 Degrees Celsius
    • Maximum Operating Voltage
      • 24 /DC voltage alternating current
    • Minimum Operating Voltage
      • 0 voltage direct current
    • Maximum Shipping & Storage Temperature
      • 70 Degrees Celsius
    • Minimum Operating Humidity
      • 5 Percentage
    • Relay Current
      • 12 ampere
    • Maximum Operating Humidity
      • 93 Percentage
    • Supply Voltage
      • 24/24
    • Minimum Operating Ambient Temperature
      • 0 Degrees Celsius
    • Maximum Operating Ambient Temperature
      • 50 Degrees Celsius
    • Relay Voltage
      • 1-29 voltage alternating current
      • 19-250 voltage alternating current
    • LED Circuit-Status Indicators
      • 3
    • Number of Outputs
      • 6
    • Input and Output Type
      • Analog
    • Relay Channels
      • 2
    • Approved Location
      • C22.2 (CNL)
      • CE
      • EN 60730-1 EN 60730-2-9
      • UL916 (USL)
    • Housing Color
      • Light Gray
    • Type
      • Relay Output Module with Terminal Socket
    • Mounting Type
      • DIN Rail

    Others

    • Minimum Shipping & Storage Temperature
      • -20 Degrees Celsius
    • Maximum Operating Voltage
      • 24 /DC voltage alternating current
    • Minimum Operating Voltage
      • 0 voltage direct current
    • Maximum Shipping & Storage Temperature
      • 70 Degrees Celsius
    • Minimum Operating Humidity
      • 5 Percentage
    • Relay Current
      • 12 ampere
    • Maximum Operating Humidity
      • 93 Percentage
    • Supply Voltage
      • 24/24
    • Minimum Operating Ambient Temperature
      • 0 Degrees Celsius
    • Maximum Operating Ambient Temperature
      • 50 Degrees Celsius
    • Relay Voltage
      • 1-29 voltage alternating current
      • 19-250 voltage alternating current
    • LED Circuit-Status Indicators
      • 3
    • Number of Outputs
      • 6
    • Input and Output Type
      • Analog
    • Relay Channels
      • 2
    • Approved Location
      • C22.2 (CNL)
      • CE
      • EN 60730-1 EN 60730-2-9
      • UL916 (USL)
    • Housing Color
      • Light Gray
    • Type
      • Relay Output Module with Terminal Socket
    • Mounting Type
      • DIN Rail
    • Minimum Shipping & Storage Temperature : -20 Degrees Celsius
    • Maximum Operating Voltage : 24 /DC voltage alternating current
    • Minimum Operating Voltage : 0 voltage direct current
    • Maximum Shipping & Storage Temperature : 70 Degrees Celsius
    • Minimum Operating Humidity : 5 Percentage
    • Relay Current : 12 ampere
    • Maximum Operating Humidity : 93 Percentage
    • Supply Voltage : 24/24
    • Minimum Operating Ambient Temperature : 0 Degrees Celsius
    • Maximum Operating Ambient Temperature : 50 Degrees Celsius
    • Relay Voltage : 1-29 voltage alternating current|19-250 voltage alternating current
    • LED Circuit-Status Indicators : 3
    • Number of Outputs : 6
    • Input and Output Type : Analog
    • Relay Channels : 2
    • Approved Location : C22.2 (CNL)|CE|EN 60730-1 EN 60730-2-9|UL916 (USL)
    • Housing Color : Light Gray
    • Type : Relay Output Module with Terminal Socket
    • Mounting Type : DIN Rail
    Sort
    Others
    Document Title
    Document Type
    Language
    Brand
    File Size
    Document Title
    Document Type
    Language
    Brand
    File Size
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime