/content/hbtbt/us/en/search-results.html

    Monitor Modules

    Addressable Monitor Module 4F

    The AMM-4F is an addressable monitor module. The AMM-4F can be configured to provide a single Style D, Class A initiating device circuit (ICD) or a single Style B, Class B IDC with a 47kΩ end-of-line resistor.

    Overview

    The Gamewell-FCI Velocity® Series, addressable monitor module (AMM-4F) features a single Style D, Class A initiating device circuit. It may also be configured as a Style B, Class B initiating circuit with end-of-line resistor. This module provides an address for any device or group of devices connected to this circuit. Any alarm initiating devices with normally open (N.O.) dry contacts, such as heat detectors, linear heat detection devices, 4-wire projected beam smoke detectors, 4-wire smoke detectors, water flow switches, tamper switches, manual stations, etc. may be installed in this circuit.

    Features & Benefits:
    • Compact size allows easy installation
    • Class A, Style D, or Class B, Style B initiating circuit
    • Visual rotary, decimal switch addressing (01-159)
    • 40 ohm line resistance for each initiating device circuit
    • Accommodates any N/O dry contact device
    • Bicolor LEDs flash green whenever the module is addressed, and light steady red on alarm*
    • *Note: Only the red LED is operative in panels that do not operate in Velocity® mode.
    Certifications:
    • UL: S1949
    • FM: 3023594
    • MEA FDNY: 277-03-E Vol. VI
    • CSFM: 7300-1703:0102
    • ISO 9001 Certification
    Specifications

    Others

    • End of Line Resistance
      • 47 kO
    • Maximum Operating Humidity
      • 0.93
    • Alarm Current
      • 0.005 ampere
    • Cabinet Depth
      • 2-1/8 inch
    • Cabinet Width
      • 4 inch
    • Cabinet Height
      • 4 inch
    • Maximum Operating Voltage
      • 15 - 32 DC volt
      • 15 VDC
    • Normal Input Current
      • 600 µA Max (communicating IDC shorted)
      • 75 µA (Group Poll)
    • For Use With
      • Manual Stations
      • Smoke Detector
      • Tamper Switches
      • Water Flow Switches
    • Maximum IDC Wiring Resistance
      • 1 500 Ohms
    • Mounting Type
      • Wall-Mount
    • Supported Wiring Configuration
      • Class B
    • Approved Location
      • CSFM 7300-1703-0102
      • FM 3023594
      • ISO 9001 Certified
      • MEA FDNY:277-03-E Vol. VI
      • UL 864 9th Edition
      • UL S1949

    Others

    • End of Line Resistance
      • 47 kO
    • Maximum Operating Humidity
      • 0.93
    • Alarm Current
      • 0.005 ampere
    • Cabinet Depth
      • 2-1/8 inch
    • Cabinet Width
      • 4 inch
    • Cabinet Height
      • 4 inch
    • Maximum Operating Voltage
      • 15 - 32 DC volt
      • 15 VDC
    • Normal Input Current
      • 600 µA Max (communicating IDC shorted)
      • 75 µA (Group Poll)
    • For Use With
      • Manual Stations
      • Smoke Detector
      • Tamper Switches
      • Water Flow Switches
    • Maximum IDC Wiring Resistance
      • 1 500 Ohms
    • Mounting Type
      • Wall-Mount
    • Supported Wiring Configuration
      • Class B
    • Approved Location
      • CSFM 7300-1703-0102
      • FM 3023594
      • ISO 9001 Certified
      • MEA FDNY:277-03-E Vol. VI
      • UL 864 9th Edition
      • UL S1949
    • End of Line Resistance : 47 kO
    • Maximum Operating Humidity : 0.93
    • Alarm Current : 0.005 ampere
    • Cabinet Depth : 2-1/8 inch
    • Cabinet Width : 4 inch
    • Cabinet Height : 4 inch
    • Maximum Operating Voltage : 15 - 32 DC volt|15 VDC
    • Normal Input Current : 600 µA Max (communicating IDC shorted)|75 µA (Group Poll)
    • For Use With : Manual Stations|Smoke Detector|Tamper Switches|Water Flow Switches
    • Maximum IDC Wiring Resistance : 1 500 Ohms
    • Mounting Type : Wall-Mount
    • Supported Wiring Configuration : Class B
    • Approved Location : CSFM 7300-1703-0102|FM 3023594|ISO 9001 Certified|MEA FDNY:277-03-E Vol. VI|UL 864 9th Edition|UL S1949
    Sort
    Others
    Document Title
    Document Type
    Language
    Brand
    File Size
    Installation Manual
    0.51 MB
    Engineering Specifications
    0.08 MB
    Engineering Specifications
    0.35 MB
    Engineering Specifications
    0.08 MB
    Engineering Specifications
    0.35 MB
    Engineering Specifications
    0.08 MB
    Engineering Specifications
    0.41 MB
    Brochure
    Document Title
    Document Type
    Language
    Brand
    File Size
    Data Sheet
    Document Title
    Document Type
    Language
    Brand
    File Size
    Catalog
    Document Title
    Document Type
    Language
    Brand
    File Size
    Document Title
    Document Type
    Language
    Brand
    File Size
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime