    AMM-2RIF Addressable Dual Input / Dual Output Module

    Addressable two I/O modules combine two relay outputs and two monitor inputs into one module device.

    Overview

    Addressable two I/O modules combine two relay outputs and two monitor inputs into one module device. The modules are capable of Class B supervised wiring used for monitored devices. They also contain Form C relay contacts, which allow the panel to switch the contacts on command. There is a dedicated LED on the module for each input and output. The fire alarm control panel can use these bi-color LEDs to indicate normal, alarm, and trouble conditions. These modules are ideally suited for areas where inputs and outputs are needed in the same location. They can be used to function with smoke/fire dampers, security doors, HVAC fans, dedicated smoke control fans, and non-dedicated smoke fans.

    The combination of two relay outputs and two monitor inputs into one device saves the cost of installing four devices. This feature can be beneficial when installing these devices in high-rise buildings or large shopping complexes. Two I/O modules are the same size as standard single modules. They can mount directly to a 4-inch (10.16 cm) square electrical box or be installed into the DNR(W) duct housing.

    Features & Benefits:
    • Offers visual rotary, decimal switch addressing (01 to 159)
    • Two sets of Class B initiating device circuits
    • Two sets of Form C relay contacts
    • Uses bi-color LEDs for each input and output, which flash when addressed and light steady when in alarm
    • Includes a DIP switch to manually disable one input and one output
    • Ideal for fan, smoke control, and door entry installations
    Certifications:
    • UL: S1949
    • CSFM: 7300-1703-0174
    • ISO 9001 Certification
    Specifications

    Others

    • Alarm Current
      • 0.024 ampere
    • End of Line Resistance
      • 47 kO
    • Normal Input Current
      • 1.3 milliampere
    • Maximum Operating Humidity
      • 0.93
    • Maximum Operating Voltage
      • 15 - 32 DC volt
      • 15 VDC
    • For Use With
      • Dedicated Smoke Control
      • Fire Damper
      • HVAC Fan
      • Non Dedicated Smoke Fan
      • Security Door
      • Smoke Damper
    • Input and Output Type
      • Relay Input
    • Approved Location
      • CSFM 7300-1703-0174
      • ISO 9001 Certified
      • UL S1949
      • UL Standard 864 9th Edition
    • Relay Channels
      • 2
    • Number of Inputs
      • 2
    • Maximum IDC Wiring Resistance
      • 1 500 Ohms
    • Relay Contact Configuration
      • Form C 2 Sets
    • Number of Outputs
      • 2
    • Supported Wiring Configuration
      • Class B

    Others

    • Alarm Current
      • 0.024 ampere
    • End of Line Resistance
      • 47 kO
    • Normal Input Current
      • 1.3 milliampere
    • Maximum Operating Humidity
      • 0.93
    • Maximum Operating Voltage
      • 15 - 32 DC volt
      • 15 VDC
    • For Use With
      • Dedicated Smoke Control
      • Fire Damper
      • HVAC Fan
      • Non Dedicated Smoke Fan
      • Security Door
      • Smoke Damper
    • Input and Output Type
      • Relay Input
    • Approved Location
      • CSFM 7300-1703-0174
      • ISO 9001 Certified
      • UL S1949
      • UL Standard 864 9th Edition
    • Relay Channels
      • 2
    • Number of Inputs
      • 2
    • Maximum IDC Wiring Resistance
      • 1 500 Ohms
    • Relay Contact Configuration
      • Form C 2 Sets
    • Number of Outputs
      • 2
    • Supported Wiring Configuration
      • Class B
    • Alarm Current : 0.024 ampere
    • End of Line Resistance : 47 kO
    • Normal Input Current : 1.3 milliampere
    • Maximum Operating Humidity : 0.93
    • Maximum Operating Voltage : 15 - 32 DC volt|15 VDC
    • For Use With : Dedicated Smoke Control|Fire Damper|HVAC Fan|Non Dedicated Smoke Fan|Security Door|Smoke Damper
    • Input and Output Type : Relay Input
    • Approved Location : CSFM 7300-1703-0174|ISO 9001 Certified|UL S1949|UL Standard 864 9th Edition
    • Relay Channels : 2
    • Number of Inputs : 2
    • Maximum IDC Wiring Resistance : 1 500 Ohms
    • Relay Contact Configuration : Form C 2 Sets
    • Number of Outputs : 2
    • Supported Wiring Configuration : Class B
    Sort
    Others
    Document Title
    Document Type
    Language
    Brand
    File Size
    Engineering Specifications
    0.08 MB
    Engineering Specifications
    0.35 MB
    Engineering Specifications
    0.08 MB
    Engineering Specifications
    0.35 MB
    Engineering Specifications
    0.08 MB
    Engineering Specifications
    0.41 MB
    Sales Sheet
    Document Title
    Document Type
    Language
    Brand
    File Size
    Data Sheet
    Document Title
    Document Type
    Language
    Brand
    File Size
    Catalog
    Document Title
    Document Type
    Language
    Brand
    File Size
    Document Title
    Document Type
    Language
    Brand
    File Size
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime
    Product Number
    Part Number
    Description
    Add to list
    AMM-2RIF
    IO Module, Addressable, 2 Monitor Input2 Relay Output