    Input monitor modules have 10 inputs and interface between a control panel and normally open contact devices in intelligent alarm systems, such as call points, security contacts, or flow switches.

    Overview

    Input monitor modules have 10 inputs and interface between a control panel and normally open contact devices in intelligent alarm systems, such as & call points, & security contacts, or flow switches. & The first address on the & module is set from 01 to 150, and the remaining modules are automatically assigned to the next nine higher addresses. Provisions are included for disabling a maximum of two unused addresses.

    The supervised state (normal, open, or short) of the monitored device is sent back to the panel. A common SLC input is used for all modules, and the initiating device loops share a common supervisory supply and ground. Otherwise, each monitor operates independently from the others. Each module has panel-controlled green LED indicators. The panel can cause the LEDs to blink, latch on, or latch off.

    Features & Benefits:
    • 10 addressable Class B or 5 addressable Class A initiating device circuits
    • Removable 18 AWG (0.9 mm²) to 12 AWG (3.25 mm²) plug-in terminal blocks
    • Status indicators for each point
    • Unused addresses may be disabled
    • Rotary address switches
    • Class A or Class B operation
    • Flexible mounting options
    • Mounting hardware included
    Certifications:
    • UL Listed: S2424
    • ULC Listed: S2424 (MMF-300-10A only)
    • CSFM Approved: 7300-0075:205
    • FM Approved
    • MEA Approved: 55-02-E
    • Listed to UL Standard 864, 9th Edition
    Specifications

    Others

    • End of Line Resistance
      • 47 kO
    • Maximum Operating Humidity
      • 93 Percentage
    • Cabinet Width
      • 10.16 centimetre
      • 4 inch
    • Cabinet Depth
      • 2.125 inch
      • 5.398 centimetre
    • Cabinet Height
      • 10.16 centimetre
      • 4 inch
    • Approved Location
      • CSFM 7300-0075-0185
      • MEA 72-01-E
      • UL S2424
      • ULC S2424
    • For Use With
      • Fire Alarm
    • Mounting Type
      • Cabinet-Mount
    • Maximum IDC Wiring Resistance
      • 1500 OHM

    Others

    • End of Line Resistance
      • 47 kO
    • Maximum Operating Humidity
      • 93 Percentage
    • Cabinet Width
      • 10.16 centimetre
      • 4 inch
    • Cabinet Depth
      • 2.125 inch
      • 5.398 centimetre
    • Cabinet Height
      • 10.16 centimetre
      • 4 inch
    • Approved Location
      • CSFM 7300-0075-0185
      • MEA 72-01-E
      • UL S2424
      • ULC S2424
    • For Use With
      • Fire Alarm
    • Mounting Type
      • Cabinet-Mount
    • Maximum IDC Wiring Resistance
      • 1500 OHM
    • End of Line Resistance : 47 kO
    • Maximum Operating Humidity : 93 Percentage
    • Cabinet Width : 10.16 centimetre|4 inch
    • Cabinet Depth : 2.125 inch|5.398 centimetre
    • Cabinet Height : 10.16 centimetre|4 inch
    • Approved Location : CSFM 7300-0075-0185|MEA 72-01-E|UL S2424|ULC S2424
    • For Use With : Fire Alarm
    • Mounting Type : Cabinet-Mount
    • Maximum IDC Wiring Resistance : 1500 OHM
    Sort
    Others
    Document Title
    Document Type
    Language
    Brand
    File Size
    Brochure
    Document Title
    Document Type
    Language
    Brand
    File Size
    Installation Instructions
    Document Title
    Document Type
    Language
    Brand
    File Size
    Manuals and Guides
    Document Title
    Document Type
    Language
    Brand
    File Size
    Data Sheet
    Document Title
    Document Type
    Language
    Brand
    File Size
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime