/content/hbtbt/us/en/search-results.html

    Monitor Modules

    NMM-100-10 Ten Input Monitor Module

    The NMM-100-10 Ten Input Modules are interface modules between FireWarden series control panel and normally open contact devices in intelligent alarm systems.These modules have panel-controlled green LED indicators.

    Overview

    The NMM-100-10 Ten-Input Monitor Modules are interface modules between a FireWarden series control panel and normally open contact devices in intelligent alarm systems such as pull stations, security contacts, or flow switches. The first address on the NMM-100-10 is set from 01 to 90 and the remaining modules are automatically assigned to the next nine higher addresses. Provisions are included for disabling a maximum of two unused addresses. The supervised state (normal, open, or short) of the monitored device is sent back to the panel. A common SLC input is used for all modules, and the initiating device loops share a common supervisory supply and ground — otherwise each monitor operates independently from the others. Each NMM-100-10 module has panel-controlled green LED indicators. The panel can cause the LEDs to blink, latch on, or latch off.

    Features & Benefits:
    • Ten addressable Class B or five addressable Class A initiating device circuits
    • Removable 12 AWG (3.31 mm²) to 18 AWG (0.821 mm²) plug-in terminal blocks
    • Status indicators for each point
    • Unused addresses may be disabled
    • Rotary address switches
    • Flexible mounting options
    • Mounting hardware included
    Certifications:
    • For NMM-100-10
    • UL Listed: S635
    • CSFM approved: 7300-0028:256
    • FM approved
    • For NMM-100-10A
    • ULC Listed: S635
    Specifications

    Others

    • Maximum IDC Wiring Resistance
      • 1500 OHM
    • Maximum Wire Gauge
      • 12
    • Minimum Wire Gauge
      • 18

    Others

    • Maximum IDC Wiring Resistance
      • 1500 OHM
    • Maximum Wire Gauge
      • 12
    • Minimum Wire Gauge
      • 18
    • Maximum IDC Wiring Resistance : 1500 OHM
    • Maximum Wire Gauge : 12
    • Minimum Wire Gauge : 18
    Sort
    Data Sheet
    Document Title
    Document Type
    Language
    Brand
    File Size
    Data Sheet
    0.60 MB
    Data Sheet
    0.57 MB
    Document Title
    Document Type
    Language
    Brand
    File Size
    Data Sheet
    0.60 MB
    Data Sheet
    0.57 MB
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime