/content/hbtbt/us/en/search-results.html

    Zone Modules

    SK-ZONE-6 Interface Module

    Addressable 6-zone interface modules transmit the status of 2-wire detector zones to Silent Knight® fire alarm control panels (FACPs). Status conditions are reported as normal, open, or alarm.

    Overview

    Addressable 6-zone interface modules transmit the status of 2-wire detector zones to Silent Knight® fire alarm control panels (FACPs). Status conditions are reported as normal, open, or alarm. The modules supervise the zones of detectors and the connection to the external power supply. The inputs on the 6-zone interface modules share a common FACP signaling line circuit (SLC) input, and the initiating device's circuits share a common external power supply. Otherwise, each input on the module operates independently from the others. If needed, you can disable a maximum of two unused inputs on the 6-zone interface module's board.

    Features & Benefits:
    • Converts a conventional 2-wire loop into an SLC loop
    • Fully supervised
    • Support for Class B and Class A wiring
    • Removable 12 to 18 AWG plug-in terminal blocks
    • Individual LED for each relay contact
    • Two module mounting in the IDP-ACB cabinet
    • Up to two unused modules can be disabled
    • Rotary address switches allow for fast installation
    • Mounting hardware included
    • Six zone inputs
    Certifications:
    • UL Listed
    Specifications

    Others

    • End of Line Resistance
      • 3.9 kO
    • Normal Input Current
      • 50 milliampere
    • Maximum Operating Humidity
      • 93 Percentage
    • Alarm Current
      • 70 milliampere
    • Maximum Operating Voltage
      • 15 - 32 DC volt
      • 15 DC volt
    • For Use With
      • 5700 Addressable Fire Alarm Control Panel
      • 5808 Addressable Fire Alarm Control Panel
      • 5820XL Addressable Fire Alarm Control Panel
      • 5820XL-EVS Addressable Fire Alarm Control Panel with an Emergency Mass Notification System
      • 6700 Addressable Fire Alarm Control Panel
      • 6808 Addressable Fire Alarm Control Panel
      • 6820 Addressable Fire Alarm Control Panel
      • 6820EVS Addressable Fire Alarm Control Panel with an Emergency Mass Notification System
    • Number of Zones
      • 6
    • Approved Location
      • UL Listed
    • Minimum Wire Gauge
      • 18
    • Maximum Wire Gauge
      • 12

    Others

    • End of Line Resistance
      • 3.9 kO
    • Normal Input Current
      • 50 milliampere
    • Maximum Operating Humidity
      • 93 Percentage
    • Alarm Current
      • 70 milliampere
    • Maximum Operating Voltage
      • 15 - 32 DC volt
      • 15 DC volt
    • For Use With
      • 5700 Addressable Fire Alarm Control Panel
      • 5808 Addressable Fire Alarm Control Panel
      • 5820XL Addressable Fire Alarm Control Panel
      • 5820XL-EVS Addressable Fire Alarm Control Panel with an Emergency Mass Notification System
      • 6700 Addressable Fire Alarm Control Panel
      • 6808 Addressable Fire Alarm Control Panel
      • 6820 Addressable Fire Alarm Control Panel
      • 6820EVS Addressable Fire Alarm Control Panel with an Emergency Mass Notification System
    • Number of Zones
      • 6
    • Approved Location
      • UL Listed
    • Minimum Wire Gauge
      • 18
    • Maximum Wire Gauge
      • 12
    • End of Line Resistance : 3.9 kO
    • Normal Input Current : 50 milliampere
    • Maximum Operating Humidity : 93 Percentage
    • Alarm Current : 70 milliampere
    • Maximum Operating Voltage : 15 - 32 DC volt|15 DC volt
    • For Use With : 5700 Addressable Fire Alarm Control Panel|5808 Addressable Fire Alarm Control Panel|5820XL Addressable Fire Alarm Control Panel|5820XL-EVS Addressable Fire Alarm Control Panel with an Emergency Mass Notification System|6700 Addressable Fire Alarm Control Panel|6808 Addressable Fire Alarm Control Panel|6820 Addressable Fire Alarm Control Panel|6820EVS Addressable Fire Alarm Control Panel with an Emergency Mass Notification System
    • Number of Zones : 6
    • Approved Location : UL Listed
    • Minimum Wire Gauge : 18
    • Maximum Wire Gauge : 12
    Sort
    Others
    Document Title
    Document Type
    Language
    Brand
    File Size
    Installation Manuals
    0.02 MB
    edam:hbt--home-and-building-technologies/languages/en_us
    0.44 MB
    Installation Manual
    0.63 MB
    Sales Sheet
    Document Title
    Document Type
    Language
    Brand
    File Size
    Brochure
    Document Title
    Document Type
    Language
    Brand
    File Size
    Installation Instructions
    Document Title
    Document Type
    Language
    Brand
    File Size
    Data Sheet
    Document Title
    Document Type
    Language
    Brand
    File Size
    Document Title
    Document Type
    Language
    Brand
    File Size
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime