/content/hbtbt/us/en/search-results.html

    Humidity Sensors

    RH-15xP-NA-xx-xx Series Duct Humidity Transmitter & Sensor

    RH-15xP-NA-xx-xx Series Duct Humidity Transmitter & Sensors convert a resistance to a linear 4 to 20 mA, 0 to 5, or 0 to 10 V DC output signal.

    Overview

    RH-15xP-NA-xx-xx Series Duct Humidity Transmitter & Sensors, convert a resistance to a linear 4 to 20 mA, 0 to 5, or 0 to 10 V DC output signal. The current transmitter may be transmitted over long distances on unshielded twisted pair wire and will not be affected by lead wire resistance or electrical noise. The Advanced Ceramic technology design overcomes the limitations of other resistance based humidity sensors that utilize water soluble polymer coatings. The Advanced Ceramic Technology enables these sensors to fully recover from condensation and allows the sensor to maintain its accuracy over a longer period of time. Despite its accuracy, the Advanced Ceramic Technology sensor and related circuitry is extremely economical.

    The accuracy is maintained over the operating range using a thermistor for temperature compensation. Precision production tolerances maintain sensor interchangeability to within +/- 3%. Field calibration can be done by using the on board increment and decrement dip switches. Each toggle will allow for a +/- 0.5% RH increase or decrease. Calibration of the 4 to 20 mA transmitter can also be done using the zero and span adjustment potentiometers. Each RH transmitter is calibrated at three different points, using an NIST Traceable Temperature / Humidity Chamber. All of these units come with a five year warranty

    Features & Benefits:
    • Advanced Ceramic technology
    • Accuracy over a longer period of time
    • High Repeatability/Hysteresis
    • Low Long Term Drift
    • Temperature Compensated
    • Calibrated to NIST Standards
    • Field Selectable Voltage Outputs
    • 2-year Factory Warranty
    Specifications

    Others

    • Maximum Operating Ambient Temperature
      • 122 degree Fahrenheit
      • 50 degree Celsius
    • Minimum Operating Ambient Temperature
      • 4.4 degree Celsius
      • 40 degree Fahrenheit
    • Detector Type
      • Duct Temperature

    Others

    • Maximum Operating Ambient Temperature
      • 122 degree Fahrenheit
      • 50 degree Celsius
    • Minimum Operating Ambient Temperature
      • 4.4 degree Celsius
      • 40 degree Fahrenheit
    • Detector Type
      • Duct Temperature
    • Maximum Operating Ambient Temperature : 122 degree Fahrenheit|50 degree Celsius
    • Minimum Operating Ambient Temperature : 4.4 degree Celsius|40 degree Fahrenheit
    • Detector Type : Duct Temperature
    Sort
    Document Title
    Document Type
    Language
    Brand
    File Size
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime
    Product Number
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list
    RH-152P-NA-DC-AA
    Humidity Transmitter, Duct-Mount, 2%, 0 to 5V DC or 0 to 10V DC Output
    RH-152P-NA-DC-AA
    Humidity Transmitter, Duct-Mount, 2%, 0 to 5V DC or 0 to 10V DC Output
    RH-152P-NA-DC-HT
    Temperature and RH Sensor, Duct-Mount, 2%, 10K Sensor, 0 to 5V DC or 0 to 10V DC Output
    RH-152P-NA-DC-HT
    Temperature and RH Sensor, Duct-Mount, 2%, 10K Sensor, 0 to 5V DC or 0 to 10V DC Output
    RH-152P-NA-MA-AA
    Humidity Transmitter, Duct-Mount, 2%, 4 to 20mA Output
    RH-152P-NA-MA-AA
    Humidity Transmitter, Duct-Mount, 2%, 4 to 20mA Output
    RH-152P-NA-MA-HT
    Temperature and RH Sensor, Duct Mount, 2%, 10K Sensor, 4 to 20mA Output
    RH-152P-NA-MA-HT
    Temperature and RH Sensor, Duct Mount, 2%, 10K Sensor, 4 to 20mA Output
    RH-153P-NA-DC-AA
    Humidity Transmitter, Duct-Mount, 3%, Accuracy, 0 to 5V DC or 0 to 10V DC Output
    RH-153P-NA-DC-AA
    Humidity Transmitter, Duct-Mount, 3%, Accuracy, 0 to 5V DC or 0 to 10V DC Output
    RH-153P-NA-DC-HT
    Temperature and RH Sensor, Duct-Mount, 3%, 10K Sensor, 0 to 5V DC or 0 to 10V DC Output
    RH-153P-NA-DC-HT
    Temperature and RH Sensor, Duct-Mount, 3%, 10K Sensor, 0 to 5V DC or 0 to 10V DC Output
    RH-153P-NA-MA-AA
    Humidity Transmitter, Duct-Mount, 3%, Accuracy, 4 to 20mA Output
    RH-153P-NA-MA-AA
    Humidity Transmitter, Duct-Mount, 3%, Accuracy, 4 to 20mA Output
    RH-153P-NA-MA-HT
    Temperature and RH Sensor, Duct-Mount, 3%, 10K Sensor, 4 to 20mA Output
    RH-153P-NA-MA-HT
    Temperature and RH Sensor, Duct-Mount, 3%, 10K Sensor, 4 to 20mA Output
    RH-155P-NA-DC-AA
    Humidity Transmitter, Duct-Mount, 5%, Accuracy, 0 to 5V DC or 0 to 10V DC Output