    Transmitter Modules

    MIP-2UD IP Communicator

    MIP-2UD IP communicators allow the transmission of alarms generated by a conventional control panel through any kind of IP network (ADSL, cable, internet), at the same time that it keeps the standard telephone line as a backup mechanism.

    Overview

    MIP-2UD IP communicators allow the transmission of alarms generated by a conventional control panel through any kind of IP network (ADSL, cable, internet), at the same time that it keeps the standard telephone line as a backup mechanism. Designed to work with the installed control panels, these communicators allow for a faster and more economic alarm transmission, improving response times, decreasing costs, and offering value-added features such as the supervised line functionality that allows the central station to detect if any of the alarm panels go offline.

    Features & Benefits:
    • Allows any contact ID burglar alarm panel to transmit alarms over IP networks
    • Saves the cost of an 800 number to receive alarms (transmission is done through a flat rate internet connection that is shared with other devices)
    • Eliminates the cost of two dedicated phone lines (only the customer’s shared IP equipment is required)
    • Can use newer low-cost, non-analog, digital telephone services such as cable or fiber optics
    • Increases connection supervision to the central station from the once-a-day test signal to once every 30 to 90 seconds
    • Requires no change to the existing panel configuration (the IP communicator connects directly to the primary and secondary analog panel telephone ports)
    • Fast alarm transmission (less than one second transmission time) for better response times to burglar alarms
    • Works over any type of customer-provided Ethernet 10/100 base network connection (LAN or WAN), DSL or cable modem
    • Data transmits over standard contact ID protocol but is secured with the industry’s highest level of encryption (AES 512-bit)
    • Supports both dynamic (DHCP) or public and private static IP addressing
    Specifications

    Others

    • Maximum Operating Voltage
      • 24 voltage direct current
    • Alarm Current
      • 104 mA @ 24 voltage direct current
      • 180 mA @ 12 voltage direct current
    • Operating Voltage
      • 10
      • 24 voltage direct current
    • Minimum Operating Ambient Temperature
      • -2 degree Celsius
      • -3 degree Fahrenheit
    • Communication Protocols
      • AES
      • DHCP
      • IP
      • RJ-45 (Female)
      • SRP
      • UDP
    • Minimum Operating Humidity
      • 0.02
    • Input Power
      • 10/24 V DC
    • Includes
      • Configuration Software
      • Manual
    • Maximum Operating Humidity
      • 0.93

    Others

    • Maximum Operating Voltage
      • 24 voltage direct current
    • Alarm Current
      • 104 mA @ 24 voltage direct current
      • 180 mA @ 12 voltage direct current
    • Operating Voltage
      • 10
      • 24 voltage direct current
    • Minimum Operating Ambient Temperature
      • -2 degree Celsius
      • -3 degree Fahrenheit
    • Communication Protocols
      • AES
      • DHCP
      • IP
      • RJ-45 (Female)
      • SRP
      • UDP
    • Minimum Operating Humidity
      • 0.02
    • Input Power
      • 10/24 V DC
    • Includes
      • Configuration Software
      • Manual
    • Maximum Operating Humidity
      • 0.93
    • Maximum Operating Voltage : 24 voltage direct current
    • Alarm Current : 104 mA @ 24 voltage direct current|180 mA @ 12 voltage direct current
    • Operating Voltage : 10|24 voltage direct current
    • Minimum Operating Ambient Temperature : -2 degree Celsius|-3 degree Fahrenheit
    • Communication Protocols : AES|DHCP|IP|RJ-45 (Female)|SRP|UDP
    • Minimum Operating Humidity : 0.02
    • Input Power : 10/24 V DC
    • Includes : Configuration Software|Manual
    • Maximum Operating Humidity : 0.93
    Sort
    Others
    Document Title
    Document Type
    Language
    Brand
    File Size
    Installation Instructions
    Document Title
    Document Type
    Language
    Brand
    File Size
    Manuals and Guides
    Document Title
    Document Type
    Language
    Brand
    File Size
    User Manual
    0.47 MB
    User Manual
    1.27 MB
    User Manual
    0.12 MB
    Document Title
    Document Type
    Language
    Brand
    File Size
    Installation Manual
    0.12 MB
    User Manual
    0.47 MB
    User Manual
    1.27 MB
    User Manual
    0.12 MB
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime
    Product Number
    Part Number
    Description
    Add to list
    MIP-2
    IP Communicator, Security no UD
    MIP-2UD
    IP Communicator for Burglar Alarm Panels