/content/hbtbt/us/en/search-results.html

    Control Modules

    SD500-ANM Addressable Notification Module

    SD500-ANM addressable notification modules provide supervised monitoring of wiring to the load devices that require an external power supply to operate such as bells, horns, and strobes.

    Overview

    SD500-ANM addressable notification modules are for use with the Honeywell Silent Knight® fire alarm control panel (FACP). SD500-ANM addressable notification modulesprovide a single class A or B circuit that is controlled by the IntelliKnight® signaling line circuit (SLC). Power for the circuit is provided to the SD500-ANM module from a separate power supply, making it easy to power remote devices. The notification circuit, remote power, and communication to the SD500-ANM are supervised by the FACP. Each notification module is programmed with a unique SLC loop address. When an event that controls the notification module occurs, the notification switches its built-in relay feeding power from the auxiliary power input to the notification appliance. SD500-ANM addressable notification modulescan produce all 16 of the notification patterns available on the fire alarm control panel.

    Features & Benefits:
    • Flexible solution for adding notification circuits where needed
    • DIP switch programming for fast installation
    • Support for Class B (Style Y) or Class A (Style Z) wiring
    • Attractive ivory cover plate
    • Polling LED visible through the cover plate
    • Adds up to 127 independent output circuits on each SLC loop
    • One auxiliary power source input
    • Completely supervised
    Certifications:
    • UL Listed, Complies with NFPA 72
    • CSFM
    • MEA 429-92-E, Vol 9
    • FM Approved
    Specifications

    Others

    • Maximum Operating Voltage
      • 24
    • Maximum Standby Current
      • 6 milliampere
    • Alarm Current
      • 56 milliampere
    • Minimum Operating Humidity
      • 0 Percentage
    • Maximum Operating Humidity
      • 93 Percentage
    • Minimum Operating Ambient Temperature
      • 0 degree Celsius
      • 32 degree Fahrenheit
    • For Use With
      • 5700:Addressable Fire Alarm Control Panel
      • 5808:Addressable Fire Alarm Control Panel
      • 5820XL-EVS:Addressable Fire Alarm Control Panel
      • 5820XL:Addressable Fire Alarm Control Panel
      • 6700:Addressable Fire Alarm Control Panel
      • 6808:Addressable Fire Alarm Control Panel
      • 6820:Addressable Fire Alarm Control Panel
      • 6820EVS:Addressable Fire Alarm Control Panel
    • Supported Wiring Configuration
      • Class A
      • Class B
    • Approved Location
      • CSFM
      • FM
      • MEA 429-92-E Vol 9
      • UL NFPA 72

    Others

    • Maximum Operating Voltage
      • 24
    • Maximum Standby Current
      • 6 milliampere
    • Alarm Current
      • 56 milliampere
    • Minimum Operating Humidity
      • 0 Percentage
    • Maximum Operating Humidity
      • 93 Percentage
    • Minimum Operating Ambient Temperature
      • 0 degree Celsius
      • 32 degree Fahrenheit
    • For Use With
      • 5700:Addressable Fire Alarm Control Panel
      • 5808:Addressable Fire Alarm Control Panel
      • 5820XL-EVS:Addressable Fire Alarm Control Panel
      • 5820XL:Addressable Fire Alarm Control Panel
      • 6700:Addressable Fire Alarm Control Panel
      • 6808:Addressable Fire Alarm Control Panel
      • 6820:Addressable Fire Alarm Control Panel
      • 6820EVS:Addressable Fire Alarm Control Panel
    • Supported Wiring Configuration
      • Class A
      • Class B
    • Approved Location
      • CSFM
      • FM
      • MEA 429-92-E Vol 9
      • UL NFPA 72
    • Maximum Operating Voltage : 24
    • Maximum Standby Current : 6 milliampere
    • Alarm Current : 56 milliampere
    • Minimum Operating Humidity : 0 Percentage
    • Maximum Operating Humidity : 93 Percentage
    • Minimum Operating Ambient Temperature : 0 degree Celsius|32 degree Fahrenheit
    • For Use With : 5700:Addressable Fire Alarm Control Panel|5808:Addressable Fire Alarm Control Panel|5820XL-EVS:Addressable Fire Alarm Control Panel|5820XL:Addressable Fire Alarm Control Panel|6700:Addressable Fire Alarm Control Panel|6808:Addressable Fire Alarm Control Panel|6820:Addressable Fire Alarm Control Panel|6820EVS:Addressable Fire Alarm Control Panel
    • Supported Wiring Configuration : Class A|Class B
    • Approved Location : CSFM|FM|MEA 429-92-E Vol 9|UL NFPA 72
    Sort
    Others
    Document Title
    Document Type
    Language
    Brand
    File Size
    Regulatory Information
    Document Title
    Document Type
    Language
    Brand
    File Size
    Sales Sheet
    Document Title
    Document Type
    Language
    Brand
    File Size
    Brochure
    Document Title
    Document Type
    Language
    Brand
    File Size
    Installation Instructions
    Document Title
    Document Type
    Language
    Brand
    File Size
    Data Sheet
    Document Title
    Document Type
    Language
    Brand
    File Size
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime