    Releasing Solenoid Interfaces by Gamewell-FCI are providing intelligent analog addressable control functionality complete with full solenoid supervision and transient voltage suppression.

    Overview

    Releasing Solenoid Interfaces by Gamewell-FCI are providing intelligent analog addressable control functionality complete with full solenoid supervision and transient voltage suppression. Only the RSI-95 can be used to actuate the releasing solenoid. The RSI-95 is automatically bypassed during a SmartStart™ or circuit initialization to prevent accidental discharge during the generic configuration, should inputs be inadvertently activated. The analog addressable RSI-95 solenoid control module is designed for use with any 600 Series FACP. To avoid unplanned fire suppressant release, the RSI-95 assembly is the ONLY assembly to be used to provide remote releasing solenoid control. The circuit can control up to two amps of DC power to the solenoid.

    Features & Benefits:
    • Compatible with the Gamewell-FCI 600 Series analog addressable fire alarm control panels
    • Provides full solenoid supervision
    • Transient voltage suppression
    • Mounts in its own unique base
    • Automatic bypass at system start-up
    • 2.0 A of DC power for solenoid.
    Certifications:
    • ISO 9000-2000 Company
    Specifications

    Others

    • Maximum Operating Humidity
      • 85 Percentage
    • Maximum Operating Voltage
      • 21Vdc from Analog Addressable Module
    • Normal Input Current
      • 6.5 milliampere
    • Alarm Current
      • 6.5 milliampere
    • For Use With
      • Gamewell-FCI 600 Series Panel
    • Relay Contact Configuration
      • 0.2A@120VAC
      • 2A@30VDC
    • Approved Location
      • UL Listed

    Others

    • Maximum Operating Humidity
      • 85 Percentage
    • Maximum Operating Voltage
      • 21Vdc from Analog Addressable Module
    • Normal Input Current
      • 6.5 milliampere
    • Alarm Current
      • 6.5 milliampere
    • For Use With
      • Gamewell-FCI 600 Series Panel
    • Relay Contact Configuration
      • 0.2A@120VAC
      • 2A@30VDC
    • Approved Location
      • UL Listed
    • Maximum Operating Humidity : 85 Percentage
    • Maximum Operating Voltage : 21Vdc from Analog Addressable Module
    • Normal Input Current : 6.5 milliampere
    • Alarm Current : 6.5 milliampere
    • For Use With : Gamewell-FCI 600 Series Panel
    • Relay Contact Configuration : 0.2A@120VAC|2A@30VDC
    • Approved Location : UL Listed
    Sort
    Engineering Specifications
    Document Title
    Document Type
    Language
    Brand
    File Size
    Engineering Specifications
    0.14 MB
    Engineering Specifications
    0.14 MB
    Engineering Specifications
    0.24 MB
    Engineering Specifications
    0.14 MB
    Engineering Specifications
    0.14 MB
    Engineering Specifications
    0.13 MB
    Data Sheet
    Document Title
    Document Type
    Language
    Brand
    File Size
    Catalog
    Document Title
    Document Type
    Language
    Brand
    File Size
    Document Title
    Document Type
    Language
    Brand
    File Size
    Engineering Specifications
    0.14 MB
    Engineering Specifications
    0.14 MB
    Engineering Specifications
    0.24 MB
    Engineering Specifications
    0.14 MB
    Engineering Specifications
    0.14 MB
    Engineering Specifications
    0.13 MB
    Name
    Description
    File Size
    Date
    Size
    No support documents tagged to this product
    An error occurred . Please try after sometime